high CVSS 7.8 EPSS 0.21%

CVE-2026-31554·Kernel vulnerability

In the Linux kernel, the following vulnerability has been resolved: futex: Require sys_futex_requeue() to have identical flags Nicholas reported that his LLM found it was possible to create a UaF when sys_futex_requeue() is used with different flags. The initial motivation for allowing different flags was the variable sized futex, but since that hasn't been merged (yet), simply mandate the flags are identical, as is the case for the old style sys_futex() requeue operations.

Severity
high
Software
Kernel
Fixed in
6.19.11
Published

How likely is exploitation

FIRST's Exploit Prediction Scoring System puts the probability of this CVE being exploited in the next 30 days at 0.21% — higher than 11% of all published CVEs. EPSS is an independent forecast of exploitation, not a severity rating: it says nothing about how much damage a successful attack does, which is what a CVSS score measures.

Read the two together. CVE-2026-31554 scores 7.8 on CVSS, so a successful attack would be serious — but at 0.21%, almost nobody is currently attempting it. That is a different situation from a flaw under mass exploitation, and it is usually the difference between patching on your next maintenance window and patching tonight.

Affected versions

From: 6.19

Until: 6.19.11

Fixed in: 6.19.11

How to fix this CVE

Update your Linux kernel to version 6.19.11 or later to resolve a use-after-free vulnerability in the futex requeue mechanism. This flaw could allow local users with sufficient privileges to trigger memory corruption by mismatching futex flags during requeue operations. Apply the kernel update and reboot your system to fully mitigate the issue.

sudo dnf update kernel kernel-devel

Defensia detects this vulnerability

How to check if you are affected

  1. Check your kernel version: uname -r — ensure it is 6.19.11 or higher, or not in the 6.19.x range
  2. Verify futex syscall tracing is enabled: cat /proc/sys/kernel/ftrace_enabled — futex-related syscalls should be logged if tracing is active
  3. Search kernel logs for futex-related errors: sudo dmesg | grep -i futex — look for UaF or memory corruption warnings
  4. Confirm the patch was applied by checking kernel build info: cat /proc/version | grep 6.19 — verify the version string reflects 6.19.11 or later

FAQ

What is CVE-2026-31554?

CVE-2026-31554 is a use-after-free vulnerability in the Linux kernel's futex requeue system that occurs when mismatched flags are passed to sys_futex_requeue(). This allows local attackers with user-level privileges to corrupt kernel memory and potentially escalate privileges.

Is CVE-2026-31554 being actively exploited?

No, CVE-2026-31554 is not listed on the CISA KEV catalog and no public exploits are currently available. However, the vulnerability was discovered through automated LLM security analysis, indicating a non-trivial attack path.

What versions of Kernel are affected by CVE-2026-31554?

Linux kernel versions 6.19 through 6.19.11 are affected. The vulnerability was patched in kernel 6.19.11 and later stable releases.

How do I check if my server is vulnerable to CVE-2026-31554?

Run 'uname -r' and compare the output against the affected range 6.19.0–6.19.10. If your kernel falls within this range, your system is vulnerable and requires immediate patching.

Does Defensia detect CVE-2026-31554?

Yes — Defensia's CVE advisory scanner compares installed package versions against the NVD database. If the Linux kernel is installed on a monitored server, CVE-2026-31554 will appear in your dashboard with remediation steps.

Related Kernel CVEs

CVE-2026-63795CVSS 10In the Linux kernel, the following vulnerability has been resolved: 9p: avoid putting oldfid in p9_client_walk() error path When p9_client_walk() is called with clone set to false, fid aliases oldfid. If the walk subsequently fails after the request has been sent, the error path jumps to clunk_fid, which currently calls p9_fid_put(fid) unconditionally. This drops a reference to oldfid even though ownership of oldfid remains with the caller. If this is the last reference, oldfid can be clunked and destroyed while the caller still expects it to be valid. A later use or put of oldfid can then trigger a use-after-free or refcount underflow. Fix this by only putting fid in the clunk_fid error path when it does not alias oldfid, matching the existing guard in the error path below. This can be triggered when a multi-component walk is split into multiple p9_client_walk() calls and a later non-cloning walk fails. A reproducer and refcount warning logs are available on request.
CVE-2026-53398CVSS 9.8In the Linux kernel, the following vulnerability has been resolved: NFSD: Fix SECINFO_NO_NAME decode error cleanup nfsd4_decode_secinfo_no_name() currently initializes sin_exp after decoding sin_style. If the XDR stream is truncated, the decoder returns nfserr_bad_xdr before sin_exp is initialized. Since commit 3fdc54646234 ("NFSD: Reduce amount of struct nfsd4_compoundargs that needs clearing"), the inline iops array is not cleared between RPC calls. A failed SECINFO_NO_NAME decode can therefore leave sin_exp holding stale union contents from a previous operation. The error response path still invokes nfsd4_secinfo_no_name_release(), which calls exp_put() on a non-NULL sin_exp. Initialize sin_exp before the first failable decode step, matching nfsd4_decode_secinfo().
CVE-2026-53399CVSS 9.8In the Linux kernel, the following vulnerability has been resolved: nfsd: release layout stid on setlease failure nfs4_alloc_stid() publishes the new stid into cl->cl_stateids via idr_alloc_cyclic() under cl_lock before returning to nfsd4_alloc_layout_stateid(). When nfsd4_layout_setlease() then fails, the error path frees the layout stateid directly with kmem_cache_free() without ever calling idr_remove(), leaving the IDR slot pointing at freed slab memory. Any subsequent IDR walker (states_show, client teardown) dereferences the dangling pointer. The correct teardown for an IDR-published stid is nfs4_put_stid(), which removes the IDR slot under cl_lock, dispatches sc_free (nfsd4_free_layout_stateid) to release ls->ls_file via nfsd4_close_layout(), and drops the nfs4_file reference in its tail. A second issue blocks that switch: nfsd4_free_layout_stateid() unconditionally inspects ls->ls_fence_work via delayed_work_pending() under ls_lock, but INIT_DELAYED_WORK(&ls->ls_fence_work, ...) currently runs only after the setlease call. On the setlease-failure path the destructor would touch an uninitialized delayed_work. nfsd4_alloc_layout_stateid() nfs4_alloc_stid() /* idr_alloc_cyclic under cl_lock */ nfsd4_layout_setlease() /* fails */ nfs4_put_stid() nfsd4_free_layout_stateid() delayed_work_pending(&ls->ls_fence_work) /* needs INIT */ nfsd4_close_layout() /* nfsd_file_put(ls->ls_file) */ put_nfs4_file() Fix by hoisting the ls_fenced / ls_fence_delay / INIT_DELAYED_WORK initialization above the nfsd4_layout_setlease() call, and replace the manual nfsd_file_put + put_nfs4_file + kmem_cache_free cleanup with a single nfs4_put_stid(stp).
CVE-2026-63800CVSS 9.8In the Linux kernel, the following vulnerability has been resolved: pNFS: Fix use-after-free in pnfs_update_layout() When hitting the NFS_LAYOUT_RETURN branch in pnfs_update_layout(), the code calls pnfs_prepare_to_retry_layoutget(lo). If it succeeds, pnfs_put_layout_hdr(lo) is called before trace_pnfs_update_layout(), which still references 'lo'. This results in a use-after-free when the tracepoint accesses lo's fields. Fix this by moving the tracepoint call before pnfs_put_layout_hdr(lo).
CVE-2026-53384CVSS 9.8In the Linux kernel, the following vulnerability has been resolved: serial: 8250_dw: unregister 8250 port if clk_notifier_register() fails dw8250_probe() registers the 8250 port via serial8250_register_8250_port() and then, if the device has a clock, registers a clock notifier. If clk_notifier_register() fails, probe returns the error but leaves the 8250 port registered. The matching serial8250_unregister_port() lives in dw8250_remove(), which is not called when probe fails, so the port slot stays occupied until the device is rebound or the system is rebooted. The devm-allocated driver data is freed while the port still references it (via the saved private_data and serial_in/serial_out callbacks), so any access to that port slot before a rebind is a use-after-free hazard. Unregister the port on the clk_notifier_register() error path.